Slave ID consumption: 2
LED indicator: Power and Link
Power supply required: 10V to +30VDC
16-CH single-ended or 8-CH differential
analog inputs(Jumper Select)
Resolution: 16-bit
Unit Conversion: Thermocouple, mV, V or mA
Input range programmable 6 levels(Bipolar):
±2.5V,
±1V, ±500mV,
±100mV, ±50mV,
±15mV,
±20mA
Input range programmable 6 levels (Unipolar):
±2.5V,
±1V, ±500mV,
±100mV, ±50mV,
±15mV,
±20mA |
Input range (Thermocouple Type, both
Unipolar and Bipolar) :
J, K, T, E, R, S, B, N, C
J: 0°C~760°C
T: -100°C~400°C
R: 500°C~1750°C
B: 500°C~1800°C
C: 0°C~2320°C
K: 0°C~1370°C
E: 0°C~1000°C
S: 500°C~1750°C
N: -270°C~1300°C
Sampling Rate(all channels) : 100Hz |
| |
|
|
|
|
|

Slave ID consumption: 2
16-CH single-ended or 8-CH differential analog input
2-CH Single-ended analog output
AD Resolution: 16-bit (14-bit guarantee)
DA Resolution: 16-bit
AD Voltage Input Range: ±10V,
±5V, ±2.5V,
±1.25V
AD Current Input Range: ±20mA |
AD Conversion Time: 10 ms
DA Settling Time: 10 ms
Over-voltage protection:±30V
LED indicator: Power and Link
Power supply: +22V to +26VDC
Operating temperature: 0 to 60°C
Storage temperature: -20 to 80°C
Power consumption: 1.8W |
| |
|
|
|
|
|

Field
I/O wiring connection for HSL I/O modules
Spring
terminal for easy field wiring
Power
and ground included for each signal channel
Interlocking
design for rugged installation
Power
LED indicator |
DIN
rail mounting
Terminator
resistor on board
I/O
Wire Gauge: 20 AWG. (max.);
28AWG. (min.)
Power
supply: 10V to +30VDC |
| |
|
|
|
|
|

Slave
ID consumption: 1
8-CH
digital input and 8-CH digital output
-NN: for NPN sinking type sensor
input or dry
contact and NPN sinking
type output
Photo
couple isolation voltage: 2500Vrms
Input
impedance: 4.7KW
Input
current: ±10mA (Max) ,
±12.5mA (Peak)
Input
voltage: ±40V (Max)
Output
switching capacity: Single channel
500mA; all channels 60mA at 24VDC
Output
response time: ON OFF: 180ms,
OFF ON: 1.2ms
LED
indicator: Power, Link and I/O status |
On
board field I/O wiring connection for
HSL I/O modules
Spring
terminal for easy field wiring
Power
and ground included (each pair of
power/ground was shared by two
I/O points)
DIN
rail mounting
Terminator
on board
I/O
Wire Gauge:
16 AWG. (max.); 24AWG. (min.)
Power
supply: 10V to +30VDC
Operating
temperature: 0 to 60°C
Storage
temperature: -20 to 80°C
Power
consumption: 1.4W |
|
|